Gas booster pressure test bench Suncenter - Air/Gas pressure test bench is compact and delicacy solution tailored to customer specific requirements with gas(air) boosters as well as all accessories to be fitted and installed in the frame or a closed cabinet. To operate this system, the pressure...
Gas booster pressure test bench
Suncenter - Air/Gas pressure test bench is compact and delicacy solution tailored to customer specific requirements with gas(air) boosters as well as all accessories to be fitted and installed in the frame or a closed cabinet.
To operate this system, the pressure gauges, valves, and pressure regulators have to be fitted on panels. The outlet pressure is easy to be set through a simple air regulator.
The pump stops automatically when this end pressure is reached and restarts with a slight drop in the outlet pressure or an increase in the air drive pressure.
Operating pressure up to 80 MPa, for higher pressure, pump with double driven heads is an ideal option.
Applications
Pressure test with gas/air
Gas transfer and filling
(Argon/Helium/Hydrogen/Oxygen/Nitrogen/CO2/NO2/CH4/LNG/LPG/CNG/FM200 etc.)
Charging of gas cylinder and accumulator with nitrogen
Supply for isolating gas systems
Gas assisted injection molding
Transfer of oxygen cylinders
Charging of breathing air bottles
Leak test
Hydrostatic Testing for valves, tanks, pressure vessels, pressure switches, hoses, pipes and tubing, pressure gauges, cylinders, transducers, well casings, BOPs, gas bottles, and aircraft components
Safety valve adjusting
DGS series air/gas booster test bench = booster pump+ following valves, gages, and parts
The hottest selling- Model C frame type cabinet picture
The standard gas booster pumps system including the following parts:
Air –driven gas booster pump (DGA/DGD/DGT three series for choosing)
Stainless steel (carbon steel) material cabinet (Three models for choosing)
F.R.L combination for driven air (adjusts air pressure, add lubricating oil and water filter)
Driven air switch (Pump starting switch), driven air pressure gauge
Gas inlet switch, Gas inlet pressure gauge
Gas outlet switch, Gas outlet pressure gauge, unloading valve, interconnecting pipes etc.
And we could also customize it according to clients’ special requirement.
DGS series air/gas pressure test bench with a round chart recorder
Technical specification for DGS-DGA series
Model | Pressure boost ratio | Min. gas Inlet pressure PA (bar) | Max.gas Inlet pressure PA (bar) | Max. gas outlet pressure PB (bar) |
Driven air pressure PL | Formula to calculate gas outlet pressure PB | Connection: Gas Inlet / Gas outlet (ZG thread) | Max. flow at driven air pressure of 6bar (L/min) |
DGS-DGA02 | 2:1 | 1.0 | 16 | 16 | 2-8 bar | 2X PL | 1/2 / 1/2 | 960 (at PA of 6 bar ) |
DGS-DGA05 | 5:1 | 0 | 40 | 40 | 2-8 bar | 5XPL | 1/2 / 1/2 | 680(at PA of 6 bar ) |
DGS-DGA10 | 10:1 | 3.5 | 80 | 80 | 2-8 bar | 10XPL | 3/8/ 3/8 | 210(at PA of 10 bar ) |
DGS-DGA25 | 25:1 | 7.0 | 200 | 200 | 2-8 bar | 25XPL | 1/4/ 1/4 | 120(at PA of 20 bar ) |
DGS-DGA40 | 40:1 | 10 | 320 | 320 | 2-8 bar | 40XPL | 1/4/ 1/4 | 200(at PA of 40 bar ) |
DGS-DGA60 | 60:1 | 20 | 480 | 480 | 2-8 bar | 60XPL | 1/4/ 1/4 | 180(at PA of 40 bar ) |
DGS-DGA100 | 100:1 | 25 | 800 | 800 | 2-8 bar | 100XPL | 1/4/ M14X1.5 | 136(at PA of 40 bar ) |
DGS-DGA130 | 130:1 | 35 | 800 | 1040 | 2-8 bar | 130XPL | 1/4/ M14X1.5 | 120(at PA of 40 bar ) |
Note: PL: driven air pressure PA: gas inlet pressure PB: gas outlet pressure
Pressure boost ratio | Min. gas Inlet pressure PA (bar) | Max.gas Inlet pressure PA (bar) | Max. gas outlet pressure PB (bar) |
Driven air pressure PL | Formula to calculate gas outlet pressure PB | Connection: Gas Inlet / Gas outlet (ZG thread) | Max. flow at driven air pressure of 6bar (L/min) | |
DGS-DGD10 | 10:1 | 3.5 | 80 | 80 | 2-8 bar | 10XPL+ PA | 3/8/3/8 | 410(at PA of 6 bar ) |
DGS-DGD25 | 25:1 | 10 | 200 | 200 | 2-8 bar | 25XPL+ PA | 1/4/1/4 | 396(at PA of 20 bar ) |
DGS-DGD40 | 40:1 | 15 | 320 | 320 | 2-8 bar | 40XPL+ PA | 1/4/1/4 | 320(at PA of 40 bar ) |
DGS-DGD60 | 60:1 | 25 | 480 | 480 | 2-8 bar | 60XPL+ PA | 1/4/1/4 | 215(at PA of 40 bar ) |
DGS-DGD100 | 100:1 | 35 | 800 | 800 | 2-8 bar | 100XPL+ PA | 1/4/M14*1.5 | 300(at PA of 60 bar ) |
The technical specification for DGS-DGD series
Note: PL: driven air pressure PA: gas inlet pressure PB: gas outlet pressure
Pressure boost ratio | Min. gas Inlet pressure PA (bar) | Max.gas Inlet pressure PA (bar) | Max. gas outlet pressure PB (bar) |
Driven air pressure PL | Formula to calculate gas outlet pressure PB | Connection: Gas Inlet / Gas outlet (ZG thread) | Max. flow at driven air pressure of 6bar (L/min) | |
DGS-DGT25 | 25:1 | 0.1 | 10 | 200 |
2-8 bar | 25XPL+3.5XPA | 1/4/ 1/4 | 136(at PA of 8 bar ) |
DGS-DGT40 | 40:1 | 0.1 | 10 | 320 |
2-8 bar | 40XPL+ 6XPA |
1/4/1/4 | 124(at PA of 8 bar ) |
DGS-DGT10/60 | 10:1/60:1 | 0.1 | 10 | 480 | 2-8 bar | 60XPL+6X PA |
1/4/1/4 | 84(at PA of 8 bar ) |
DGS-DGT25/60 | 25:1/60:1 | 10 | 25 | 480 |
2-8 bar | 60XPL+2.5XPA |
1/4/1/4 | 80(at PA of 15 bar ) |
DGS-DGT100 | 100:1 | 0.1 | 10 | 800 | 2-8 bar | 100XPL+10XPA | 1/4/ M14*1.5 | 63(at PA of 8 bar ) |
The technical specification for DGS-DGT series