Gas Booster Pressure Test Bench

Gas booster pressure test bench Suncenter - Air/Gas pressure test bench is compact and delicacy solution tailored to customer specific requirements with gas(air) boosters as well as all accessories to be fitted and installed in the frame or a closed cabinet. To operate this system, the pressure...

Product Details

Gas booster pressure test bench

 

Suncenter - Air/Gas pressure test bench is compact and delicacy solution tailored to customer specific requirements with gas(air) boosters as well as all accessories to be fitted and installed in the frame or a closed cabinet.

To operate this system, the pressure gauges, valves, and pressure regulators have to be fitted on panels. The outlet pressure is easy to be set through a simple air regulator.

The pump stops automatically when this end pressure is reached and restarts with a slight drop in the outlet pressure or an increase in the air drive pressure.

Operating pressure up to 80 MPa, for higher pressure, pump with double driven heads is an ideal option.

 

Applications

Pressure test with gas/air

Gas transfer and filling

(Argon/Helium/Hydrogen/Oxygen/Nitrogen/CO2/NO2/CH4/LNG/LPG/CNG/FM200 etc.)

Charging of gas cylinder and accumulator with nitrogen

Supply for isolating gas systems

Gas assisted injection molding

Transfer of oxygen cylinders

Charging of breathing air bottles

Leak test

Hydrostatic Testing for valves, tanks, pressure vessels, pressure switches, hoses, pipes and tubing, pressure gauges, cylinders, transducers, well casings, BOPs, gas bottles, and aircraft components

Safety valve adjusting

 

DGS series air/gas booster test bench = booster pump+ following valves, gages, and parts

 

image 

 

The hottest selling- Model C frame type cabinet picture

image 

 

 

 

The standard gas booster pumps system including the following parts:

Air –driven gas booster pump (DGA/DGD/DGT three series for choosing)

 

Stainless steel (carbon steel) material cabinet (Three models for choosing)

 

F.R.L combination for driven air (adjusts air pressure, add lubricating oil and water filter)

 

Driven air switch (Pump starting switch), driven air pressure gauge

 

Gas inlet switch, Gas inlet pressure gauge

 

Gas outlet switch, Gas outlet pressure gauge,  unloading valve, interconnecting pipes etc.

 

And we could also customize it according to clients’ special requirement.

 

 

DGS series air/gas pressure test bench with a round chart recorder

image 

 

 

 

Technical specification for DGS-DGA series

Model

Pressure boost ratio

Min. gas

Inlet pressure

PA (bar)

Max.gas

Inlet pressure

PA (bar)

Max. gas

outlet pressure PB (bar)

 

Driven air pressure  PL

Formula to

calculate gas outlet pressure PB

Connection:

Gas Inlet /

Gas outlet (ZG thread)

Max. flow at driven air pressure of 6bar (L/min)

DGS-DGA02

2:1

1.0

16

16

2-8 bar

2X PL

1/2 / 1/2

960 (at PA of 6 bar )

DGS-DGA05

5:1

0

40

40

2-8 bar

5XPL

1/2 / 1/2

680(at PA of 6 bar )

DGS-DGA10

10:1

3.5

80

80

2-8 bar

10XPL

3/8/ 3/8

210(at PA of 10 bar )

DGS-DGA25

25:1

7.0 

200

200

2-8 bar

25XPL

1/4/ 1/4

120(at PA of 20 bar )

DGS-DGA40

40:1

10

320

320

2-8 bar

40XPL

1/4/ 1/4

200(at PA of 40 bar )

DGS-DGA60

60:1

20 

480

480

2-8 bar

60XPL

1/4/ 1/4

180(at PA of 40 bar )

DGS-DGA100

100:1

25

800

800

2-8 bar

100XPL

1/4/ M14X1.5

136(at PA of 40 bar )

DGS-DGA130

130:1

35

800

1040

2-8 bar

130XPL

1/4/ M14X1.5

120(at PA of 40 bar )

 

Note:  PL: driven air pressure   PA: gas inlet pressure   PB: gas outlet pressure  

 

 

Model

Pressure boost ratio

Min. gas

Inlet pressure

PA (bar)

Max.gas

Inlet pressure

PA (bar)

Max. gas

outlet pressure PB (bar)

 

Driven air pressure  PL

Formula to

calculate gas outlet pressure PB

Connection:

Gas Inlet /

Gas outlet (ZG thread)

Max. flow at driven air pressure of 6bar (L/min)

DGS-DGD10

10:1

3.5

80

80

2-8 bar

10XPL+ PA

3/8/3/8

410(at PA of 6 bar )

DGS-DGD25

25:1

10

200

200

2-8 bar

25XPL+ PA

1/4/1/4

396(at PA of 20 bar )

DGS-DGD40

40:1

15

320

320

2-8 bar

40XPL+ PA

1/4/1/4

320(at PA of 40 bar )

DGS-DGD60

60:1

25

480

480

2-8 bar

60XPL+ PA

1/4/1/4

215(at PA of 40 bar )

DGS-DGD100

100:1

35

800

800

2-8 bar

100XPL+ PA

1/4/M14*1.5

300(at PA of 60 bar )

 The technical specification for DGS-DGD series

 

Note:  PL: driven air pressure   PA: gas inlet pressure   PB: gas outlet pressure  

 

Model

Pressure boost ratio

Min. gas

Inlet pressure

PA (bar)

Max.gas

Inlet pressure

PA (bar)

Max. gas

outlet pressure PB (bar)

 

Driven air pressure  PL

Formula to

calculate gas outlet pressure PB

Connection:

Gas Inlet /

Gas outlet (ZG thread)

Max. flow at driven air pressure of 6bar (L/min)

DGS-DGT25

25:1

0.1

10

200

 

2-8 bar

25XPL+3.5XPA

1/4/ 1/4

136(at PA of 8 bar )

DGS-DGT40

40:1

0.1

10

320

 

2-8 bar

40XPL+ 6XPA

 

1/4/1/4

124(at PA of 8 bar )

 DGS-DGT10/60

10:1/60:1

0.1

10

480

2-8 bar

60XPL+6X PA

 

1/4/1/4

84(at PA of 8 bar )

DGS-DGT25/60

25:1/60:1

10

25

480

 

2-8 bar

60XPL+2.5XPA

 

1/4/1/4

80(at PA of 15 bar )

DGS-DGT100

100:1

0.1

10

800

2-8 bar

100XPL+10XPA

1/4/ M14*1.5

63(at PA of 8 bar )

The technical specification for DGS-DGT series

 

Note:  PL: driven air pressure   PA: gas inlet pressure   PB: gas outlet pressure  