Air Hydraulic Pump DGG Series

Air hydraulic pump DGG series Air hydraulic pump DGG series MOQ:1 Set Brand Name: SUNCENTER Certificate:ISO/CE/SGS Warranty:13 Months Packaging: by Plywood case Shipping Port: Shenzhen/Hongkong Payment: T/T, Western Union, Credit card. Transaction method:EXW,FOB,DDP,CIF,CFR Place of Origin:...

Product Details

Air hydraulic pump DGG series

Air hydraulic pump DGG series

 

MOQ:1 Set

Brand Name: SUNCENTER

Certificate:ISO/CE/SGS

Warranty:13 Months

Packaging: by Plywood case

Shipping Port: Shenzhen/Hongkong

Payment: T/T, Western Union, Credit card.

Transaction method:EXW,FOB,DDP,CIF,CFR

Place of Origin: Guangdong Province, China (Mainland)

Delivery Time: Within 10-15 working days after received deposit.

 

Compressed Air Driven Hydraulic Pump-DGG Series

We offer the most complete range of Air driven liquid pump models in the industry measured for:

A. The capability of ultimate pressure, flow or output horsepower.

B. Compatibility with a broad variety of liquids, such as oil, water, and chemical applications.

SUNCENTER pumps are air driven at a drive air pressure of 1bar to 8bar (14.5 psi to116 psi) by the normal air compressor. Basically, the principle of operation is similar to a reciprocating amplifier where control of the piston at the end position is regulated by a pilot operated 4/2 way valve.

 

Suncenter pumps feature a large air piston joint to a smaller diameter plunger. The pressure ratio is the difference of these two areas and is the method of determining maximum outlet pressure. Higher pressures obtained by using higher pressure ratios. Suncenter model numbers reflect the pumps nominal pressure ratios, while the technical data indicates exact ratios. The outlet pressure is easily to set through a simple air regulator. By multiplying the pressure ratio by the available shop air pressure, the nominal liquid pressure can be calculated.

 

SUNCENTER pumps are self priming. In general it is not necessary to use an air line lubricator. 

The liquid to be pumped flows into the suction chamber by the up-stroke of the drive piston. By this suction effect, the inlet check valve is opened and the outlet check valve is closed. The down-stroke generates the pressure at the liquid side. The inlet check valve is closed and the outlet check valve is opened by the generated pressure. SUNCENTER liquid pumps cycle automatically, where the pressure is built up the numbers of cycles slow down, the pump stops automatically when the output pressure forces are equal. The pump restarts with a slight drop in the outlet pressure or an increase in the air drive pressure. Pump performance can be affected by a number of conditions, such as freezing of muffler or pilot valves (which is caused by moisture in air lines), inadequate inlet air line sizes and dirty filers. Don’t reduce the indicated port sizes and consult SUNCENTER for exact flow conditions not shown in charts.

 

    

Applications include:

 

l  Pressure testing

l  Burst(Hydrostatic) testing

l  Work holding/power clamping

l  Jacking/lifting

l  Valve actuator control

l  Hydraulic cylinder actuation

l  Press safety overload devices

l  Roller tensioning

l  Metering

l  Precision lubrication and spraying

l  Liquefied gas transfer

 

 

Key features include:

 

Compressed Air driven - no electricity required (connect to normal air compressor)

In order to extend the lifetime of the pump, the driving air pressure should

not be higher than 8 bar

No airline lubricator required

Pressures to 640Mpa (6400 bar)  

Wide range of models with different ratios

Built-in-cooling on most models

Easy to install, operate and maintain

Best price / performance ratio

No heat, flame or spark risk and explosion proof

Automatic pressure holding, whatever the cause of the pressure drop, the Suncenter   pump will automatically start, keep the loop pressure constant

 

image

 

DGG Series Liquid Pumps(Single acting, single air drive head)

l DGG pumps have aluminum bodies and wetted materials of stainless steel or carbon steel ,which

  depends on different service liquid. Materials of stainless steel, make them an excellent choice

of water application. High quality seals, long service life available.

image

Technical specification

 

Model

Pressure  Boost Ratio

Driven air pressure PL 

Formula to calculate outlet pressure

MAX Outlet

Pressure(bar)*

Liquid inlet Connection

Liquid outlet Connection

MAX Flow (L/min) 

DGG6

6:1

2-8 bar

6XPL

48

NPT1/2

NPT1/2

29.91

DGG10

10:1

2-8 bar

10XPL

80

NPT1/2

NPT1/2

18.84

DGG16

16:1

2-8 bar

16XPL

128

NPT1/2

NPT1/2

12.42

DGG28

28:1

2-8 bar

28XPL

224

NPT1/2

NPT1/2

7.11

DGG40

40:1

2-8 bar

40XPL

320

NPT1/2

NPT1/2

4.89

DGG64

64:1

2-8 bar

64XPL

512

NPT1/2

NPT3/8

3.08

DGG80

80:1

2-8 bar

80XPL

640

NPT1/2

NPT3/8

2.44

DGG100

100:1

2-8 bar

100XPL

800

NPT1/2

NPT3/8

1.92

DGG130

130:1

2-8 bar

130XPL

1040

NPT1/2

M14X1.5

1.47

DGG175

175:1

2-8 bar

175XPL

1400

NPT3/8

M14X1.5

1.14

DGG255

255:1

2-8 bar

255XPL

2040

NPT1/4

M14X1.5

0.75

DGG400

400:1

2-8 bar

400XPL

3200

NPT1/4

M14X1.5

0.48

DGG510

510:1

2-8 bar

510XPL

4080

NPT1/4

M14X1.5

0.65

DGG800

800:1

2-8 bar

800XPL

6400

NPT1/4

M14X1.5

0.42

 

The outlet liquid pressure=Driven air pressure*boost ratio

In order to extend the lifetime of the pump, the driving air pressure should not be higher than 8 bar

 

Suncenter DLS Series Pneumatic (Air driven) Liquid Booster System

Suncenter- DLS Series Pneumatic(Air driven) Hydraulic Power Packs 

SUNCENTER- Hydraulic power packs(Liquid pump system) are compact and delicacy solution tailored to customer specific requirements with air driven liquid pumps as well as all accessories to be fitted and installed on the frame or in closed cabinet.

To operate this system, the pressure gauges, valves and pressure regulators have to be fitted on panels. The outlet pressure is easily to be set through a simple air regulator. The pump stops automatically when this end pressure is reached and restarts with a slight drop in the outlet pressure or an increase in the air drive pressure. SUNCENTER Hydraulic power packs are available with wide range of pressure ratios make these series of pumps ideal for powering a variety of oil/hydraulic operations. The maximum operating pressure up to 640 MPa.

As the pressure will be generated by means of a pneumatically operated pump,the electric connection will not be necessary. To operate this system, the air driven liquid pump have to be equipped with the air control unit combined filter and water separator, pressure-regulating valve, pressure control gauge as well as manual relieve valve. In this operation, the pump will be mounted to the stainless steel tank in the closed cabinet in a compact and space saving manner. Pressure gauges, valves and pressure regulators will be fitted on panel.

The desired operating pressure can be attained by adjusting the driving air pressure. When the driving air pressure and the output pressure reach the balance, the pump stops filling pressure and the output pressure stays at the preset value. This hydraulic unit can be used for all kinds of pressure testing and test tools for research and test institutes or for other functions requiring a determined pressure. 

 

image 

DLS Liquid (hydraulic) booster system = Liquid pump+ following valves, gages, and parts

 

 

The standard liquid pump system including following parts:

Air –driven liquid booster pump (DGM/DGG/DGGD Three series for choosing)

Stainless steel (carbon steel) material cabinet (Three models for choosing)

F.R.L combination for driven air (adjusts air pressure, add lubricating oil and water filter)

Driven air switch (Pump starting switch), driven air pressure gauge, water tank

Liquid inlet/outlet switch, high pressure liquid guage, unloading valve, interconnecting pipes etc.

And we could also customize it according to clients’ special requirement.

 

DLS series Liquid Pressure Booster Pump System-The hottest selling Model C cabinet

 

image 

 

 

 

 

 

 

How to Select Suncenter Air Driven Liquid Boosters/Systems?

In order to choose suitable liquid booster pump or systems for you,

please kindly reply us the following questions:

 

1.What is the liquid you want to booster?

 

2. What outlet liquid pressure do you want?(    )bar

 

3. What driven air pressure (of your air compressor) can you offer?(    )bar,

Because our booster is completely air operated and no need any electricity

 

4. What outlet liquid flow rate do you need?(    )L/min


Hot Tags: air hydraulic pump dgg series, manufacturers, suppliers, factory
Inquiry